F1600 RFI Filters
Speci ? cations :
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current:
115VAC 250VAC
3A 1.5A
Features:
? T Section, Dual Coil Design – High Insertion Loss for
Switching Power Supply Emissions
? Low-Leakage Current Design
? Space-Efficient with Integral IEC Connector and
Compact Case in Current Ratings up to 10Amps
? Available in Fused IEC Connector and PC Mounted
Versions
F1600CX Simpli ? ed Schematic
6A 3A
10A 6A
Current Overload: 6X for 8 seconds
Hi-Pot Test (1 min):
Line to Ground 1500VAC
Line to Line 1768VDC
Insulation Resistance: 9 x 10 9 Ω at 100VDC
Ambient Temperature: 40°C Max. at rated current
Humidity Range: 0% to 95% R.H.
Termination:
A: QC – Quick Connect
L
G
L
B: Wire
C: IEC Receptacle
P: PC – P.C. Board
N
N
Maximum Leakage Current:
Each Line to Ground
F1600
F1600FA Simpli ? ed Schematic
L
G
N
L
N
115VAC, 60Hz: 0.25mA
250VAC, 50Hz: 0.40mA
Agency Approvals:
Nominal
Current
Rating
Part
Number
Termination
Line/Load
MODE
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
Frequency - MHz
.15 .50 1.0 5.0 10
30
F1600CA03
IEC/QC
3A
F1600CP03
F1600FA03
IEC/PC
Fused IEC/QC
Common
Differential
52
40
65
50
65
60
65
65
65
65
65
50
F1600CB03
F1600CA06
IEC/Wire
IEC/QC
6A
F1600CP06
F1600FA06
IEC/PC
Fused IEC/QC
Common
Differential
45
30
65
45
65
55
65
50
65
50
59
50
F1600CB06
IEC/Wire
10A
F1600CA10
F1600CB10
IEC/QC
IEC/Wire
Common
Differential
50
23
65
45
65
55
65
50
65
50
54
50
NOTE: Other combinations of terminals may be speci ? ed on special order.